Microchannel Plate with Solid Border MCP 18-10
Microchannel Plate is intended for operation in vacuum inside Image Intensifier Tubes as a multi-channel secondary-electron multiplier of electron images.
Alternative specification may be made on customer’s order.
Size-shape factors | ||
Parameter |
Dimension |
Value |
Outside Diameter | mm | 24.8 |
Active Area Diameter | mm | not less than 18.6 |
Plate Thickness | mm | 0.43 |
Pore Size | um | 10 |
Channel Pitch | um | 12 |
Channel Bias | degrees | 5 |
Electrical and Image Characteristics | ||
Parameter |
Dimension |
Value |
Electron Gain at 800 V | - | 1000 |
Resistance | ×108 Ohms | 1.5 - 4 |
Minimum Limiting Resolution | lp/mm | 50 |
Maximum Dark Current Density | ×10-14 A/cm2 | 1 |
Noise factor, typical value | - | 2.5 |
Open Area Ratio | % | not less than 59 |
MTTF (mean time to failure) – not less than 7500 hrs.
Absolute maximum ratings | ||
Description |
Units |
Limiting Value |
Operating Voltage | V | 1000 |
Field Strength | V/mm | 14000 |
Input Current Density | ×10-8 A/cm2 | 1 |
Output Current Density | ×10-7 A/cm2 | 4 |
Vacuum Bakeout Limiting Temperature: 440° С during not more than 6 hrs. at 5×10-6Torr.
Warranties:
Shelf-life: the MCP shall be stored in container provided by the manufacturer during 6 months, in vacuum (1.33×10-3Pa) during 1 year or 15 years as a part of an image intensifier tube. The shelf-life is to be calculated from the acceptance date of manufacturer’s quality inspection, and in a case of reacceptance from the reacceptance date.