{"id":718,"date":"2022-09-25T18:46:19","date_gmt":"2022-09-25T15:46:19","guid":{"rendered":"https:\/\/baspik.com\/?page_id=718"},"modified":"2025-11-16T12:25:51","modified_gmt":"2025-11-16T09:25:51","slug":"customized-mcps","status":"publish","type":"page","link":"https:\/\/baspik.com\/en\/products\/microchannel-plates\/customized-mcps\/","title":{"rendered":"Customized MCPs"},"content":{"rendered":"\n<div class=\"wp-block-columns are-vertically-aligned-center is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"is-style-emphasis has-primary-color has-text-color has-medium-font-size\">VTC BASPIK is a company with many years of experience in the field of development of microchannel plates for various tasks of Russian and foreign consumers. The terms of a custom order depend on the parameters of the expected product, the volume of delivery, the urgency of development and some other factors.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:30%\">\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img decoding=\"async\" src=\"https:\/\/baspik.com\/wp-content\/uploads\/2022\/12\/mkp56-15-1024x1020.webp\" alt=\"\" class=\"wp-image-1893\" style=\"width:278px;height:276px\"\/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><img loading=\"lazy\" decoding=\"async\" width=\"7\" height=\"2\" src=\"\">Examples of custom-designed products<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Microchannel plates with a shaped contact electrode<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\">Schematic diagram<\/h4>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/baspik.com\/wp-content\/uploads\/2022\/12\/mkp-s-figurnym-kontaktnym-elektrodom-1024x349.webp\" alt=\"\" class=\"wp-image-1708\"\/><\/figure>\n\n\n<figure class=\"wp-block-table\">\n<table>\n<thead>\n<tr>\n<th rowspan=\"3\">Parameter, unit<\/th>\n<th colspan=\"2\">Microchannel plate type<\/th>\n<\/tr>\n<tr>\n<th>Rimmed MCP 25-10 S<\/th>\n<th>Rimmed MCP 25-12 S<\/th>\n<\/tr>\n<tr>\n<th colspan=\"2\">Nominal value<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td colspan=\"3\">\n<h6>Geometrics<\/h6>\n<\/td>\n<\/tr>\n<tr>\n<td>Outer diameter D, mm<\/td>\n<td colspan=\"2\">32<\/td>\n<\/tr>\n<tr>\n<td>Active area diameter, DA, mm<\/td>\n<td colspan=\"2\">25.5<\/td>\n<\/tr>\n<tr>\n<td>Thickness L, mm<\/td>\n<td>0.38<br \/>0.46<\/td>\n<td>0.46<\/td>\n<\/tr>\n<tr>\n<td>Channel bias angle \u03b8, degrees<\/td>\n<td colspan=\"2\">8\u00b0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<h6>Structural parameters<\/h6>\n<\/td>\n<\/tr>\n<tr>\n<td>Channel diameter, \u03bcm<\/td>\n<td>9.5<\/td>\n<td>12<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<h6>Electrical ratings<\/h6>\n<\/td>\n<\/tr>\n<tr>\n<td>Operating voltage at gain of 10<sup>3<\/sup>, V, max<\/td>\n<td colspan=\"2\">850<\/td>\n<\/tr>\n<tr>\n<td>MCP resistance, \u00d710<sup>8<\/sup>Ohm<\/td>\n<td colspan=\"2\">1.0\u20135.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n\n\n<h3 class=\"wp-block-heading\">Microchannel plates with central hole<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\">Schematic diagram<\/h4>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"386\" height=\"244\" src=\"https:\/\/baspik.com\/en\/wp-content\/uploads\/sites\/5\/2023\/04\/microchannel-plates-with-central-holeschematic-diagram.webp\" alt=\"\" class=\"wp-image-2673\" style=\"width:560px\" srcset=\"https:\/\/baspik.com\/en\/wp-content\/uploads\/sites\/5\/2023\/04\/microchannel-plates-with-central-holeschematic-diagram.webp 386w, https:\/\/baspik.com\/en\/wp-content\/uploads\/sites\/5\/2023\/04\/microchannel-plates-with-central-holeschematic-diagram-300x190.webp 300w\" sizes=\"auto, (max-width: 386px) 100vw, 386px\" \/><\/figure>\n\n\n<figure class=\"wp-block-table\">\n<table>\n<thead>\n<tr>\n<th rowspan=\"3\">Parameter, unit<\/th>\n<th colspan=\"2\">Microchannel plate type<\/th>\n<\/tr>\n<tr>\n<th>MCP 35-15 CH<\/th>\n<th>MCP 50-15 CH<\/th>\n<\/tr>\n<tr>\n<th colspan=\"2\">Nominal value<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td colspan=\"3\">\n<h6>Geometrics<\/h6>\n<\/td>\n<\/tr>\n<tr>\n<td>Outer diameter D1, mm<\/td>\n<td>32.7<\/td>\n<td>56<\/td>\n<\/tr>\n<tr>\n<td>Hole diameter D2, mm<\/td>\n<td>7.45<\/td>\n<td>24<\/td>\n<\/tr>\n<tr>\n<td>Active area ring limited by DA1-DA2 diameters, mm<\/td>\n<td>26.7\u20139<\/td>\n<td>54.2\u201326.8<\/td>\n<\/tr>\n<tr>\n<td>Thickness L, mm<\/td>\n<td>0.7<\/td>\n<td>0.75<\/td>\n<\/tr>\n<tr>\n<td>Channel bias angle \u03b8, degrees<\/td>\n<td>5\u00b0\u20139\u00b0<\/td>\n<td>7\u00b0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<h6>Structural parameters<\/h6>\n<\/td>\n<\/tr>\n<tr>\n<td>Channel diameter, \u03bcm<\/td>\n<td colspan=\"2\">15<\/td>\n<\/tr>\n<tr>\n<td>Channel pitch, \u00b5m<\/td>\n<td colspan=\"2\">19<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<h6>Electrical ratings<\/h6>\n<\/td>\n<\/tr>\n<tr>\n<td>Operating voltage at gain of 10<sup>4<\/sup>, V, max<\/td>\n<td colspan=\"2\">1100<\/td>\n<\/tr>\n<tr>\n<td>MCP resistance, \u00d710<sup>8<\/sup> Ohm<\/td>\n<td colspan=\"2\">1\u201310<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n\n\n<h3 class=\"wp-block-heading\">Microchannel plates with annular segment<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\">Schematic diagram<\/h4>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" src=\"https:\/\/baspik.com\/wp-content\/uploads\/2022\/12\/mkp-s-uglovym-segmentom.webp\" alt=\"\" class=\"wp-image-1707\" style=\"width:665px\"\/><\/figure>\n\n\n<figure class=\"wp-block-table\">\n<table>\n<thead>\n<tr>\n<th rowspan=\"3\">Parameter, unit<\/th>\n<th colspan=\"2\">Microchannel plate type<\/th>\n<\/tr>\n<tr>\n<th>MCP 43.5LR<\/th>\n<th>MCP 50LR<\/th>\n<\/tr>\n<tr>\n<th colspan=\"2\">Nominal value<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td colspan=\"3\">\n<h6>Geometrics<\/h6>\n<\/td>\n<\/tr>\n<tr>\n<td>Outside radius R1, mm<\/td>\n<td>43.5<\/td>\n<td>50<\/td>\n<\/tr>\n<tr>\n<td>Hole radius R2, mm<\/td>\n<td>33<\/td>\n<td>17<\/td>\n<\/tr>\n<tr>\n<td>Active area radius R3, R4, mm<\/td>\n<td>\u00a0 40.5, 36<\/td>\n<td>\u00a0 47, 20<\/td>\n<\/tr>\n<tr>\n<td>Thickness L, mm<\/td>\n<td colspan=\"2\">1<\/td>\n<\/tr>\n<tr>\n<td>Annular segment \u03b81, \u03b82, degree<\/td>\n<td>\u00a0 118\u00b0, 118\u00b0<\/td>\n<td>\u00a0 112\u00b0, 112\u00b0<\/td>\n<\/tr>\n<tr>\n<td>Channel bias angle \u03b8, degrees<\/td>\n<td colspan=\"2\">8\u00b0<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<h6>Structural parameters<\/h6>\n<\/td>\n<\/tr>\n<tr>\n<td>Channel diameter, \u03bcm<\/td>\n<td colspan=\"2\">25<\/td>\n<\/tr>\n<tr>\n<td>Channel pitch, \u00b5m<\/td>\n<td colspan=\"2\">32<\/td>\n<\/tr>\n<tr>\n<td colspan=\"3\">\n<h6>Electrical ratings<\/h6>\n<\/td>\n<\/tr>\n<tr>\n<td>Gain at MCP voltage of 1000 V, min<\/td>\n<td colspan=\"2\">10000<\/td>\n<\/tr>\n<tr>\n<td>MCP resistance, \u00d710<sup>6<\/sup> Ohm<\/td>\n<td>4-6<\/td>\n<td>5-11<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>","protected":false},"excerpt":{"rendered":"<p>VTC BASPIK is a company with many years of experience in the field of development of microchannel plates for various tasks of Russian and foreign consumers. The terms of a custom order depend on the parameters of the expected product, the volume of delivery, the urgency of development and some other factors. Examples of custom-designed [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":636,"menu_order":5,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"footnotes":""},"tags":[34,10],"class_list":["post-718","page","type-page","status-publish","hentry","tag-customized-mcps","tag-microchannel-plates"],"_links":{"self":[{"href":"https:\/\/baspik.com\/en\/wp-json\/wp\/v2\/pages\/718","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/baspik.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/baspik.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/baspik.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/baspik.com\/en\/wp-json\/wp\/v2\/comments?post=718"}],"version-history":[{"count":3,"href":"https:\/\/baspik.com\/en\/wp-json\/wp\/v2\/pages\/718\/revisions"}],"predecessor-version":[{"id":3254,"href":"https:\/\/baspik.com\/en\/wp-json\/wp\/v2\/pages\/718\/revisions\/3254"}],"up":[{"embeddable":true,"href":"https:\/\/baspik.com\/en\/wp-json\/wp\/v2\/pages\/636"}],"wp:attachment":[{"href":"https:\/\/baspik.com\/en\/wp-json\/wp\/v2\/media?parent=718"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/baspik.com\/en\/wp-json\/wp\/v2\/tags?post=718"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}