{"id":2348,"date":"2023-02-18T03:47:46","date_gmt":"2023-02-18T00:47:46","guid":{"rendered":"https:\/\/baspik.com\/?page_id=2348"},"modified":"2024-10-01T03:55:21","modified_gmt":"2024-10-01T00:55:21","slug":"tof-detector-with-a-built-in-voltage-divider","status":"publish","type":"page","link":"https:\/\/baspik.com\/en\/products\/detectors\/open-detectors\/time-of-flight-detectors-tof-for-mass-spectrometry\/tof-detector-with-a-built-in-voltage-divider\/","title":{"rendered":"TOF detector with a built-in voltage divider"},"content":{"rendered":"\n<div class=\"wp-block-columns are-vertically-aligned-center is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"is-style-emphasis has-primary-color has-text-color has-medium-font-size\">TOF detector with a built-in voltage divider, mounted on a printed circuit board, is designed for detection of charged particle fluxes as part of a mass spectrometer<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img decoding=\"async\" src=\"https:\/\/baspik.com\/wp-content\/uploads\/2023\/02\/veu-s-platoj-lezha.52-1024x703.webp\" alt=\"\" class=\"wp-image-2386\" style=\"width:342px;height:235px\"\/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p>Detectors for time-of-flight mass spectrometers must have a high-speed response without &#8220;damped&#8221; oscillations (TOF detectors) and must detect ions with high efficiency. Therefore, MCP detectors, which have high ion sensitivity, sub-nanosecond response time and are compact, are mainly used as such detectors.<\/p>\n\n\n\n<p>The board used to assemble the MCP detector contains the detector voltage divider, power supply circuit components, and a coaxial connector for signal acquisition. Assembly of the detector with the board allows to reduce the influence of spurious inductances and capacitances, as a result the output pulse of the MCP-detector acquires a classical waveform without &#8220;damped&#8221; oscillations and has a short width (less than 1 ns). The compact design, with 2 inputs for voltage supply and a coaxial connector for signal acquisition, is more adaptable to the application and allows easy installation and replacement of the detector when needed.<\/p>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-4 wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-medium\"><a href=\"https:\/\/baspik.com\/wp-content\/uploads\/2023\/02\/veu-s-platoj.42.webp\"><img decoding=\"async\" data-id=\"2396\" src=\"https:\/\/baspik.com\/wp-content\/uploads\/2023\/02\/veu-s-platoj.42-300x300.webp\" alt=\"\" class=\"wp-image-2396\"\/><\/a><\/figure>\n\n\n\n<figure class=\"wp-block-image size-medium\"><a href=\"https:\/\/baspik.com\/wp-content\/uploads\/2023\/02\/veu-s-platoj.45.webp\"><img decoding=\"async\" data-id=\"2393\" src=\"https:\/\/baspik.com\/wp-content\/uploads\/2023\/02\/veu-s-platoj.45-300x300.webp\" alt=\"\" class=\"wp-image-2393\"\/><\/a><\/figure>\n\n\n\n<figure class=\"wp-block-image size-medium\"><a href=\"https:\/\/baspik.com\/wp-content\/uploads\/2023\/02\/veu-s-platoj.48.webp\"><img decoding=\"async\" data-id=\"2394\" src=\"https:\/\/baspik.com\/wp-content\/uploads\/2023\/02\/veu-s-platoj.48-300x300.webp\" alt=\"\" class=\"wp-image-2394\"\/><\/a><\/figure>\n\n\n\n<figure class=\"wp-block-image size-medium\"><a href=\"https:\/\/baspik.com\/wp-content\/uploads\/2023\/02\/veu-s-platoj.50.webp\"><img decoding=\"async\" data-id=\"2395\" src=\"https:\/\/baspik.com\/wp-content\/uploads\/2023\/02\/veu-s-platoj.50-300x300.webp\" alt=\"\" class=\"wp-image-2395\"\/><\/a><\/figure>\n<\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Specification<\/h3>\n\n\n\n<h5 class=\"wp-block-heading\">Basic parameters<\/h5>\n\n\n<figure class=\"wp-block-table\">\n<table>\n<thead>\n<tr>\n<th rowspan=\"2\">Parameter, unit<\/th>\n<th colspan=\"2\">Value<\/th>\n<\/tr>\n<tr>\n<th>min<\/th>\n<th>max<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>MCP active area diameter, mm<\/td>\n<td>26<\/td>\n<td>\u00a0<\/td>\n<\/tr>\n<tr>\n<td>Supply voltage at 1\u00d710<sup>7<\/sup> gain, V<\/td>\n<td><sup>\u00a0<\/sup> <sup>\u00a0<\/sup><\/td>\n<td>2400<\/td>\n<\/tr>\n<tr>\n<td>Single electron pulse height resolution, %<\/td>\n<td>\u00a0<\/td>\n<td>130<\/td>\n<\/tr>\n<tr>\n<td>Dark count rate density, count\/sec\u00d7cm<sup>2<\/sup><\/td>\n<td>\u00a0<\/td>\n<td>2<\/td>\n<\/tr>\n<tr>\n<td>Average pulse width (FWHM), ns<\/td>\n<td>\u00a0<\/td>\n<td>0.85<\/td>\n<\/tr>\n<tr>\n<td>Pulse leading edge rise time, ns<\/td>\n<td>\u00a0<\/td>\n<td>0.5<\/td>\n<\/tr>\n<tr>\n<td>Product consumption current at supply voltage, \u03bcA<\/td>\n<td>\u00a0 \u00a0<\/td>\n<td>\u00a0 250<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/figure>\n\n\n<h5 class=\"wp-block-heading\">Typical output waveform<\/h5>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" src=\"https:\/\/baspik.com\/wp-content\/uploads\/2024\/03\/tof-tipichnaya-forma-vyhodnogo-impulsa.webp\" alt=\"\" class=\"wp-image-3177\"\/><\/figure>\n\n\n\n<h5 class=\"wp-block-heading\">The detector electrical connection diagram<\/h5>\n\n\n\n<div class=\"wp-block-group is-layout-flex wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"340\" height=\"360\" src=\"https:\/\/baspik.com\/en\/wp-content\/uploads\/sites\/5\/2023\/04\/the-detector-electrical-connection-diagram.webp\" alt=\"\" class=\"wp-image-2646\"\/><\/figure>\n\n\n\n<div class=\"wp-block-group has-global-padding is-layout-constrained wp-block-group-is-layout-constrained\">\n<p>R1 = 10 M\u03a9;<br>R2 = R3 = 1 M\u03a9;<br>\u04211 = \u04212 = 470 pF;<br>U<sub>supply<\/sub> = -2.4 kV, max<\/p>\n\n\n\n<p>1 &#8211; control electrode;<br>2 &#8211; MCP unit;<br>3 &#8211; anode<\/p>\n<\/div>\n<\/div>\n\n\n\n<h5 class=\"wp-block-heading\">General view, overall, setting and mounting dimensions of MCP detector with 25 mm active area diameter<\/h5>\n\n\n\n<div class=\"wp-block-group is-layout-flex wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"372\" height=\"294\" src=\"https:\/\/baspik.com\/en\/wp-content\/uploads\/sites\/5\/2023\/04\/mkp-na-pechatnoj-plate-shema1en.webp\" alt=\"\" class=\"wp-image-2906\" srcset=\"https:\/\/baspik.com\/en\/wp-content\/uploads\/sites\/5\/2023\/04\/mkp-na-pechatnoj-plate-shema1en.webp 372w, https:\/\/baspik.com\/en\/wp-content\/uploads\/sites\/5\/2023\/04\/mkp-na-pechatnoj-plate-shema1en-300x237.webp 300w\" sizes=\"auto, (max-width: 372px) 100vw, 372px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"373\" height=\"294\" src=\"https:\/\/baspik.com\/en\/wp-content\/uploads\/sites\/5\/2023\/04\/mkp-na-pechatnoj-plate-shema2en.webp\" alt=\"\" class=\"wp-image-2907\" srcset=\"https:\/\/baspik.com\/en\/wp-content\/uploads\/sites\/5\/2023\/04\/mkp-na-pechatnoj-plate-shema2en.webp 373w, https:\/\/baspik.com\/en\/wp-content\/uploads\/sites\/5\/2023\/04\/mkp-na-pechatnoj-plate-shema2en-300x236.webp 300w\" sizes=\"auto, (max-width: 373px) 100vw, 373px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"328\" height=\"294\" src=\"https:\/\/baspik.com\/en\/wp-content\/uploads\/sites\/5\/2023\/04\/mkp-na-pechatnoj-plate-shema3en.webp\" alt=\"\" class=\"wp-image-2908\" srcset=\"https:\/\/baspik.com\/en\/wp-content\/uploads\/sites\/5\/2023\/04\/mkp-na-pechatnoj-plate-shema3en.webp 328w, https:\/\/baspik.com\/en\/wp-content\/uploads\/sites\/5\/2023\/04\/mkp-na-pechatnoj-plate-shema3en-300x269.webp 300w\" sizes=\"auto, (max-width: 328px) 100vw, 328px\" \/><\/figure>\n<\/div>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>Lead designation<\/th><th> <\/th><\/tr><\/thead><tbody><tr><td>1<\/td><td>Supply voltage \u20132400 V, max<\/td><\/tr><tr><td>2. 3<\/td><td>Package<\/td><\/tr><tr><td>SMA<\/td><td>Signal output<\/td><\/tr><tr><td>\u0410<\/td><td>Anode<\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>TOF detector with a built-in voltage divider, mounted on a printed circuit board, is designed for detection of charged particle fluxes as part of a mass spectrometer Detectors for time-of-flight mass spectrometers must have a high-speed response without &#8220;damped&#8221; oscillations (TOF detectors) and must detect ions with high efficiency. Therefore, MCP detectors, which have high [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":2953,"menu_order":1,"comment_status":"closed","ping_status":"closed","template":"","meta":{"inline_featured_image":false,"footnotes":""},"tags":[6,44,59],"class_list":["post-2348","page","type-page","status-publish","hentry","tag-detectors","tag-open-detectors","tag-tof-detectors"],"_links":{"self":[{"href":"https:\/\/baspik.com\/en\/wp-json\/wp\/v2\/pages\/2348","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/baspik.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/baspik.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/baspik.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/baspik.com\/en\/wp-json\/wp\/v2\/comments?post=2348"}],"version-history":[{"count":2,"href":"https:\/\/baspik.com\/en\/wp-json\/wp\/v2\/pages\/2348\/revisions"}],"predecessor-version":[{"id":3020,"href":"https:\/\/baspik.com\/en\/wp-json\/wp\/v2\/pages\/2348\/revisions\/3020"}],"up":[{"embeddable":true,"href":"https:\/\/baspik.com\/en\/wp-json\/wp\/v2\/pages\/2953"}],"wp:attachment":[{"href":"https:\/\/baspik.com\/en\/wp-json\/wp\/v2\/media?parent=2348"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/baspik.com\/en\/wp-json\/wp\/v2\/tags?post=2348"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}