Detector with rectangular MCP 43x63, the section collector and separated supply

Detector is intended for the registration of the charged particles of nuclear radiation in the scientific and industrial equipment. The detector consists of MCP-stack, metal-ceramic fittings and a sectional collector. The section form corresponds to the equilateral triangle. Operating position the detector is any. The operating principle is based on the registration and amplification of the input current of the charged particles, and determination of particle impact position.

Detector's view
Dimensional outlines
Physical Characteristics

Parameter

Dimension

Value

MCP Pore Sizeum12
Bias Angledegree7
Active Areamm39 × 59
Maximum Detector Dimensionsmm94 × 60
Maximum Detector Heightmm12
Number of MCP-2
Electrical Characteristics

Parameter

Dimension

Value

Minimum gain-1×107
Maximum Single-electron pulse height resolution%130
Maximum Dark Pulses Count Rate Densitycps/cm-23
MCP ResistanceΩ5×107÷2×108
Maximum Operating VoltageV2800
Vacuum ≤Pa (Torr)1,3×10-4 (1×10-6)
Circuit diagram